Sentinel HEPA P100 Cartridges (25 Packs of 2)
SKU: S-4002-25




SKU: S-4002-25
- HEPA P100 cartridges: NIOSH-approved particulate filters for Sentinel XL HP and Sentinel XT PAPRs.
- 99.97% filtration: remove at least 99.97% of airborne particles 0.3 microns and larger, and the media is strongly oil resistant.
- Particulates only: not for gases or vapors; where solvent vapors or acid gases are present, use S-4012 OV/AG/HE cartridges.
- 40 mm threaded connection: magenta NIOSH color code.
- 25 packs of 2: 25 full sets, with 2 cartridges per blower, sized for emergency departments, central supply and outbreak reserve.
- Also available: 3 packs of 2, sized for departmental stock.
- Product ID: ILC Dover S-4002-25
Need assistance?
Our team can help with volume orders, payment options, and product questions.
$1,826.00
Prices for items exclude shipping costs and taxes. Depending on your delivery address, taxes may vary at checkout.The Sentinel HEPA P100 Cartridges (S-4002) are the particulate filters for Sentinel XL HP and Sentinel XT powered air-purifying respirators (PAPRs). Classified as HEPA and P100, they remove at least 99.97% of airborne particles 0.3 microns and larger, which covers bacteria, respiratory aerosols and fine powders. The filter media is strongly resistant to oil, and each cartridge threads into a 40 mm port on the Sentinel XL blower.
Use them where the only hazard is airborne particles: infectious disease and airborne isolation care, outbreak response, and pharmaceutical work such as blending, milling, weighing and dispensing where powders are handled with no gas or vapor present. On the Sentinel XL, they pair with the Sentinel XL Head Cover (APF 25), the Sentinel XL Clear Hood and the Sentinel XL BioShield Full Hood (APF 1,000), and they come with every Sentinel XL HP system and HP conversion kit.
HEPA cartridges do not protect against gases or vapors. If solvent vapors or acid gases are present, use Sentinel XL Organic Vapor/Acid Gas/HEPA Cartridges (S-4012), which add chemical protection to HEPA filtration. For CBRN work, use Sentinel XL CBRN CAP 2 Cartridges (S-2016) with the CBRN butyl hood.
Each Sentinel blower takes 2 cartridges, so 25 packs of 2 give you 25 complete changes, sized for emergency departments, central supply and outbreak reserve. For departmental stock, choose 3 packs of 2. Check airflow with the Sentinel Flow Meter before use.
ILC Dover recommends inspecting your system after each use. Replace any cartridge with mechanical damage, and change cartridges out according to your location's change-out schedule and the user instructions.
What's included
- 25 packs of two S-4002 HEPA cartridges (50 cartridges, 25 blower sets)
- Blower, hood and battery are sold separately.
Key specifications
- Filtration: HEPA (HE), P100, greater than 99.97% DOP filtration efficiency, strongly oil resistant
- Not for: gases or vapors
- Interface: 40 mm threaded
- NIOSH color code: magenta
- Cartridges per blower: 2
- Compatible with: Sentinel XL head cover, clear hood and BioShield full hood on the Sentinel XL blower; Sentinel XT PAPR systems
Which Sentinel cartridge do I need?
All three cartridge types thread into the same 40 mm ports on the Sentinel XL blower, so the choice comes down to the hazard you are protecting against.
|
Sentinel HEPA P100 Cartridges S-4002 |
Sentinel XL OV/AG/HE Cartridges S-4012 |
Sentinel XL CBRN CAP 2 Cartridges S-2016 |
|
|---|---|---|---|
| Filtration | HEPA (P100) particulate filter | Combination: organic vapor, acid gas and HEPA | CBRN cartridge |
| NIOSH color code | Magenta | Magenta and yellow | Olive |
| Protects against | Airborne particles, including dusts, powders and bioaerosols. 99.97% filtration efficiency, strongly oil resistant. | Organic vapors and acid gases, including chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide and hydrogen fluoride, plus HEPA particulate filtration. | Chemical warfare agents, toxic industrial chemicals, biological threats and nuclear particulates. |
| Not for | Gases or vapors | Ammonia, formaldehyde or CBRN agents | HP head covers and hoods (use S-4002 or S-4012 with those) |
| Typical uses | Infectious disease and airborne isolation care; pharmaceutical powder handling with no gas or vapor hazard | Pharmaceutical and chemical processing with solvent vapors; disinfection with peracetic acid and hydrogen peroxide products | Hospital decontamination, hazmat and emergency response, government and military CBRN programs |
| Hoods and head covers |
Sentinel XL Head Cover Sentinel XL Clear Hood Sentinel XL BioShield Full Hood |
Sentinel XL Head Cover Sentinel XL Clear Hood Sentinel XL BioShield Full Hood |
Sentinel XL CBRN Butyl Hood Assembly with Breathing Tube |
| Cartridges per blower | 2 | 3 | 3 |
| Pack sizes |
3 packs of 2 (3 blower sets) 25 packs of 2 (25 blower sets) |
Pack of 3 (1 blower set) | Pack of 3 (1 blower set) |
All Sentinel cartridges are air-purifying and do not supply oxygen, so none are for use in oxygen-deficient atmospheres. Use each cartridge only in the Sentinel configurations listed on its NIOSH approval label, and follow the user instructions.