Sentinel XL HP Head Cover PAPR Conversion Kit
SKU: S-3000-05



SKU: S-3000-05
- Head cover HP conversion kit: the head cover, breathing tube and HEPA cartridges to convert a compatible Sentinel XL system, such as the Sentinel XL HP PAPR Base Kit or a Sentinel XL CBRN system.
- APF 25 protection: 2.5 times the protection of an N95, with no fit testing.
- Stethoscope-compatible: the head cover provides a wide field of view and easily accommodates stethoscopes.
- Single size, anti-glare visor: one size eliminates the need to stock multiple sizes, and a chin panel reduces visor glare.
- Compatible filters: HEPA cartridges are included, and the head cover also accepts S-4012 OV/AG/HE cartridges (sold separately) for hazardous-drug protection.
- Also available: replacement head covers in packs of 3 and packs of 25.
- Product ID: ILC Dover S-3000-05
$212.09
Prices for items exclude shipping costs and taxes. Depending on your delivery address, taxes may vary at checkout.The Sentinel XL HP Head Cover PAPR Conversion Kit includes the head cover, breathing tube and HEPA cartridges. It converts a compatible Sentinel XL system, such as the Sentinel XL HP PAPR Base Kit or a Sentinel XL CBRN system, to a head cover HP configuration for infectious-disease protection.
The head cover has an assigned protection factor (APF) of 25, or 2.5 times the protection of an N95, and requires no fit testing.
The head cover provides a wide field of view and easily accommodates stethoscopes. A single size eliminates the need to buy and stock multiple sizes, and the cushioned head strap supports a wide range of wearers. Its impact-resistant, optical-grade polycarbonate visor includes a chin panel that reduces visor glare, and a threaded connection secures the breathing tube.
The Head cover can also be used with S-4012 OV/AG/HE cartridges (sold separately) for hazardous-drug protection. Replacement head covers are available in packs of 3 and packs of 25, and HP conversion kits are also available for the clear hood and BioShield full hood.
What's included
- S-4001 Sentinel XL Head Cover
- S-4005 Sentinel Breathing Tube
- S-4002 Sentinel HEPA P100 Cartridges
- Blower, battery and waist belt are not included.
Key specifications
- Protection: APF 25, 2.5 times the protection of an N95, no fit testing
- Head cover: coated spun-bonded polyolefin, single size, impact-resistant optical-grade polycarbonate visor with anti-glare chin panel, cushioned head strap, threaded breathing tube connection
- Filters: S-4002 HEPA P100 cartridges
- Breathing tube: polyurethane coating over a rigid plastic helix
- Compatible with: Sentinel XL blower systems, such as the Sentinel XL HP PAPR Base Kit (S-3000-12) and Sentinel XL CBRN systems
- Latex-free
Which Sentinel XL conversion kit do I need?
A conversion kit changes what a Sentinel XL protects against without replacing the system. The blower, battery and waist belt stay in place, and you swap the head top and the cartridges.
| Conversion kit | Use it for | Protection | Head top included | Cartridges included |
|---|---|---|---|---|
| HP Head Cover PAPR Conversion Kit S-3000-05 | Infectious disease care | APF 25 2.5 times the protection of an N95 | S-4001 Head Cover Wide field of view, accommodates stethoscopes | Two S-4002 HEPA P100 |
| HP Clear Hood PAPR Conversion Kit S-3000-19 | Infectious disease care | APF 1,000 100 times the protection of an N95 | S-3101 Clear Hood 320-degree field of view, no internal suspension | Two S-4002 HEPA P100 |
| HP BioShield Full Hood PAPR Conversion Kit S-3000-24 | Infectious disease care where blood-borne pathogens are a concern | APF 1,000 100 times the protection of an N95 | S-2028 BioShield Full Hood Taped seams pass ASTM F 1670-14 and ASTM F 1671-13 | Two S-4002 HEPA P100 |
| HD BioShield Full Hood PAPR Conversion Kit S-3000-31 | Hazardous drug handling, for USP <800> respiratory protection | APF 1,000 100 times the protection of an N95 | S-2028 BioShield Full Hood Taped seams pass ASTM F 1670-14 and ASTM F 1671-13 | Three S-4012 OV/AG/HE |
| CBRN PAPR Conversion Kit S-5000-05 | Decon teams, including hospital decon and first receivers | CAP 2 NIOSH CBRN CAP 2 with a 10,000 LRPL once assembled | S-2001 Butyl Hood Assembly Lay-flat design, breathing tube integral to the hood | Three S-2016 CBRN CAP 2 |
Every kit fits the same Sentinel XL blower. The blower, battery and waist belt are not included, so you need an existing system or the Sentinel XL HP PAPR Base Kit. The four HP and HD kits supply the S-4005 breathing tube; the CBRN kit's breathing tube is part of the butyl hood and the kit also includes the CBRN CAP 2 user's manual. All head tops are single size, loose fitting, latex free and need no fit testing. These are air-purifying configurations that do not supply oxygen, so none are for use in oxygen-deficient atmospheres. NIOSH approvals apply to complete assemblies: use each kit only in the Sentinel configurations listed on the approval label, and follow the user instructions.