Sentinel XL HD BioShield Full Hood PAPR Conversion Kit
SKU: S-3000-31



SKU: S-3000-31
- BioShield HD conversion kit: the BioShield full hood, breathing tube and OV/AG/HE cartridges to convert a compatible Sentinel XL system for USP 800 hazardous-drug protection, such as the Sentinel XL HP PAPR Base Kit or a Sentinel XL CBRN system.
- NIOSH approved for hazardous drugs: the Sentinel XL with BioShield hood is NIOSH approved with OV/AG/HE cartridges, for higher-level respiratory protection against hazardous drugs than N95s.
- APF 1,000 protection: 100 times the protection of an N95, with no fit testing.
- OV/AG/HE cartridges: S-4012 cartridges for organic vapors, acid gases and high-efficiency (HE) particulate filtration.
- ASTM F1670 and F1671 tested: the hood and its sewn and taped seams pass ASTM F1670-14 (synthetic blood) and ASTM F1671-13 (blood-borne pathogens) testing.
- Double-skirted design: internal and external skirts interface with most protective suits, with PAPR airflow venting between the two skirts.
- Also available: the HP version with HEPA cartridges, and replacement BioShield hoods in packs of 3 and packs of 25.
- Product ID: ILC Dover S-3000-31
$452.00
Prices for items exclude shipping costs and taxes. Depending on your delivery address, taxes may vary at checkout.The Sentinel XL HD BioShield Full Hood PAPR Conversion Kit includes the BioShield full hood, breathing tube and S-4012 OV/AG/HE cartridges. It converts a compatible Sentinel XL system, such as the Sentinel XL HP PAPR Base Kit or a Sentinel XL CBRN system, to a hazardous-drug protection configuration for USP 800 respiratory protection.
The Sentinel XL with BioShield hood is NIOSH approved with OV/AG/HE cartridges, providing higher-level respiratory protection against hazardous drugs than N95s. The hood has an assigned protection factor (APF) of 1,000, or 100 times the protection of an N95, and requires no fit testing. S-4012 OV/AG/HE cartridges are designated for organic vapors (OV), acid gases (AG) and high-efficiency particulate filtration (HE).
The protective hood and its sewn and taped seams pass ASTM F1670-14 and ASTM F1671-13 testing, which the CDC requires for protection against synthetic blood and blood-borne pathogen penetration. Internal and external skirts interface with most protective suits. PAPR airflow vents between the two skirts, and the skirt and exhaust system inflates the suit for improved protection and comfort. The hood has an ultra-clear PET visor and a cushioned head strap that supports a wide range of wearers in a single size.
For infectious-disease protection, the Sentinel XL HP BioShield Full Hood PAPR Conversion Kit pairs the same hood with HEPA cartridges. Replacement BioShield hoods are available in packs of 3 and packs of 25.
What's included
- S-2028 Sentinel XL BioShield Full Hood
- S-4005 Sentinel Breathing Tube
- S-4012 Sentinel XL Organic Vapor/Acid Gas/HEPA Cartridges
- Blower, battery and waist belt are not included.
Key specifications
- Protection: APF 1,000, 100 times the protection of an N95, no fit testing
- Hazardous drugs: NIOSH approved with OV/AG/HE cartridges (USP 800 respiratory protection)
- BioShield hood: coated spun-bonded polyolefin, sewn and taped seams passing ASTM F1670-14 and ASTM F1671-13, internal and external skirts, ultra-clear PET visor, cushioned head strap, single size
- Filters: S-4012 OV/AG/HE cartridges
- Breathing tube: polyurethane coating over a rigid plastic helix
- Compatible with: Sentinel XL blower systems, such as the Sentinel XL HP PAPR Base Kit (S-3000-12) and Sentinel XL CBRN systems
- Latex-free
Which Sentinel XL conversion kit do I need?
A conversion kit changes what a Sentinel XL protects against without replacing the system. The blower, battery and waist belt stay in place, and you swap the head top and the cartridges.
| Conversion kit | Use it for | Protection | Head top included | Cartridges included |
|---|---|---|---|---|
| HP Head Cover PAPR Conversion Kit S-3000-05 | Infectious disease care | APF 25 2.5 times the protection of an N95 | S-4001 Head Cover Wide field of view, accommodates stethoscopes | Two S-4002 HEPA P100 |
| HP Clear Hood PAPR Conversion Kit S-3000-19 | Infectious disease care | APF 1,000 100 times the protection of an N95 | S-3101 Clear Hood 320-degree field of view, no internal suspension | Two S-4002 HEPA P100 |
| HP BioShield Full Hood PAPR Conversion Kit S-3000-24 | Infectious disease care where blood-borne pathogens are a concern | APF 1,000 100 times the protection of an N95 | S-2028 BioShield Full Hood Taped seams pass ASTM F 1670-14 and ASTM F 1671-13 | Two S-4002 HEPA P100 |
| HD BioShield Full Hood PAPR Conversion Kit S-3000-31 | Hazardous drug handling, for USP <800> respiratory protection | APF 1,000 100 times the protection of an N95 | S-2028 BioShield Full Hood Taped seams pass ASTM F 1670-14 and ASTM F 1671-13 | Three S-4012 OV/AG/HE |
| CBRN PAPR Conversion Kit S-5000-05 | Decon teams, including hospital decon and first receivers | CAP 2 NIOSH CBRN CAP 2 with a 10,000 LRPL once assembled | S-2001 Butyl Hood Assembly Lay-flat design, breathing tube integral to the hood | Three S-2016 CBRN CAP 2 |
Every kit fits the same Sentinel XL blower. The blower, battery and waist belt are not included, so you need an existing system or the Sentinel XL HP PAPR Base Kit. The four HP and HD kits supply the S-4005 breathing tube; the CBRN kit's breathing tube is part of the butyl hood and the kit also includes the CBRN CAP 2 user's manual. All head tops are single size, loose fitting, latex free and need no fit testing. These are air-purifying configurations that do not supply oxygen, so none are for use in oxygen-deficient atmospheres. NIOSH approvals apply to complete assemblies: use each kit only in the Sentinel configurations listed on the approval label, and follow the user instructions.