Sentinel XL CBRN PAPR Conversion Kit
SKU: S-5000-05





SKU: S-5000-05
- CBRN CAP 2 conversion: turns a Sentinel XL HP PAPR into a NIOSH CBRN CAP 2 configuration with a 10,000 LRPL, for hospital decon and first receiver teams.
- Lay-flat butyl hood: the S-2001 butyl hood assembly with integral breathing tube, single size with no fit testing.
- Three CBRN cartridges: one full set of S-2016 CBRN CAP 2 cartridges with 40 mm threads, in hermetically sealed foil pouches.
- One blower, two applications: keeps the existing Sentinel XL blower, battery and waist belt, reducing costs and simplifying inventory.
- User's manual included: the kit ships with the CBRN CAP 2 user's manual.
- Product ID: ILC Dover S-5000-05
Need assistance?
Our team can help with volume orders, payment options, and product questions.
$1,029.99
Prices for items exclude shipping costs and taxes. Depending on your delivery address, taxes may vary at checkout.The Sentinel XL CBRN PAPR Conversion Kit converts a Sentinel XL HP system into a NIOSH-approved CBRN CAP 2 configuration for emergency preparedness decon teams, including hospital decon and first receiver teams. A hospital that already runs Sentinel XL HP PAPRs for infectious-disease protection can equip its decon team on the same blower platform, reducing costs and simplifying equipment inventory.
The kit replaces the head cover or hood, breathing tube and HEPA cartridges with the lay-flat Sentinel XL CBRN Butyl Hood Assembly with Breathing Tube, whose breathing tube is an integral part of the hood, and a full set of three CBRN CAP 2 cartridges. The blower, battery and waist belt stay in place. Assembled on the Sentinel XL blower, the kit provides the CBRN CAP 2 protection of the Sentinel XL CBRN systems, with a 10,000 LRPL against military warfare agents, biological threats, industrial chemical threats and nuclear particulate threats.
The single-size butyl hood requires no fit testing, and its cushioned antimicrobial head strap has five adjustment positions to support a wide range of wearers. The lay-flat design reduces storage issues.
Teams without an existing Sentinel XL system can choose a complete Sentinel XL CBRN Standard PAPR System or Sentinel XL CBRN Deluxe PAPR System instead.
What's included
- S-2001 Sentinel XL CBRN Butyl Hood Assembly with Breathing Tube
- Three S-2016 CBRN CAP 2 cartridges
- CBRN CAP 2 user's manual
- Blower, battery and waist belt are not included.
Key specifications
- Protection when assembled: NIOSH CBRN CAP 2, 10,000 LRPL
- CBRN cartridges: CAP 2, three per kit, 40 mm military/NATO-style interface, hermetically sealed foil pouches
- Hood: single size, butyl-coated fabric, sewn and taped seams, impact-resistant optical-grade polycarbonate visor, M40-style silicone exhaust valve, cushioned antimicrobial head strap with five adjustment positions
- Breathing tube: flexible, reinforced with a butyl sheath, integral part of the hood
- Compatible with: Sentinel XL blower with the rechargeable NiMH or alkaline battery pack
Which Sentinel XL conversion kit do I need?
A conversion kit changes what a Sentinel XL protects against without replacing the system. The blower, battery and waist belt stay in place, and you swap the head top and the cartridges.
| Conversion kit | Use it for | Protection | Head top included | Cartridges included |
|---|---|---|---|---|
| HP Head Cover PAPR Conversion Kit S-3000-05 | Infectious disease care | APF 25 2.5 times the protection of an N95 | S-4001 Head Cover Wide field of view, accommodates stethoscopes | Two S-4002 HEPA P100 |
| HP Clear Hood PAPR Conversion Kit S-3000-19 | Infectious disease care | APF 1,000 100 times the protection of an N95 | S-3101 Clear Hood 320-degree field of view, no internal suspension | Two S-4002 HEPA P100 |
| HP BioShield Full Hood PAPR Conversion Kit S-3000-24 | Infectious disease care where blood-borne pathogens are a concern | APF 1,000 100 times the protection of an N95 | S-2028 BioShield Full Hood Taped seams pass ASTM F 1670-14 and ASTM F 1671-13 | Two S-4002 HEPA P100 |
| HD BioShield Full Hood PAPR Conversion Kit S-3000-31 | Hazardous drug handling, for USP <800> respiratory protection | APF 1,000 100 times the protection of an N95 | S-2028 BioShield Full Hood Taped seams pass ASTM F 1670-14 and ASTM F 1671-13 | Three S-4012 OV/AG/HE |
| CBRN PAPR Conversion Kit S-5000-05 | Decon teams, including hospital decon and first receivers | CAP 2 NIOSH CBRN CAP 2 with a 10,000 LRPL once assembled | S-2001 Butyl Hood Assembly Lay-flat design, breathing tube integral to the hood | Three S-2016 CBRN CAP 2 |
Every kit fits the same Sentinel XL blower. The blower, battery and waist belt are not included, so you need an existing system or the Sentinel XL HP PAPR Base Kit. The four HP and HD kits supply the S-4005 breathing tube; the CBRN kit's breathing tube is part of the butyl hood and the kit also includes the CBRN CAP 2 user's manual. All head tops are single size, loose fitting, latex free and need no fit testing. These are air-purifying configurations that do not supply oxygen, so none are for use in oxygen-deficient atmospheres. NIOSH approvals apply to complete assemblies: use each kit only in the Sentinel configurations listed on the approval label, and follow the user instructions.