ILC Dover logo

Sentinel XL® HP

Sentinel XL HP PAPR Systems: Complete Kits for Infectious Disease and Hazardous Drug Protection

The Sentinel XL HP is ILC Dover's NIOSH-approved loose-fitting powered air-purifying respirator (PAPR) for healthcare professionals, built around the rugged, dual-chamber Sentinel XL blower. This page lists the four ways to buy it: three complete systems that arrive ready to use with a head cover, clear hood or BioShield full hood, and a base kit that supplies the durable hardware for you to finish with the hood and cartridges you need. Every system is sold direct by ILC Dover, the manufacturer, and none requires fit testing.

APF 1,000

With the clear hood or BioShield full hood

230+ lpm

Blower airflow in HP hood systems

8–10 h

Nominal runtime, NiMH or alkaline

<75 dB

Blower noise level, 1.0 lb without battery

What Comes in Each Sentinel XL HP System

All four share the same blower, flow meter, breathing tube, waist belt and duffel bag. The differences are the head top, the cartridges and the power source:

Component Standard
S-3000-01
Clear Hood
S-3000-16
BioShield
S-3000-23
Base Kit
S-3000-12
Head top Head cover, APF 25 Clear hood, APF 1,000 BioShield full hood, APF 1,000 Not included
HEPA P100 cartridges ✓ ✓ ✓ Not included
Power NiMH battery and Smart Battery Charger Alkaline battery pack Alkaline battery pack NiMH battery and Smart Battery Charger
Sentinel XL blower ✓ ✓ ✓ ✓
Flow meter, breathing tube, Quick-Loc waist belt, duffel bag ✓ ✓ ✓ ✓

Which Sentinel XL HP System to Choose

Pick the system that matches the head top your task needs and how often the unit will be worn.

Sentinel XL HP Standard System

SKU S-3000-01

Choose it for: routine airborne isolation in daily rotation. The stethoscope-compatible head cover gives APF 25, and the rechargeable battery charges in the blower between shifts.

View product →

Sentinel XL HP Clear Hood System

SKU S-3000-16

Choose it for: APF 1,000 with a 320 degree field of view and room for most head, hearing and eye protection. Alkaline power suits reserve and surge units.

View product →

Sentinel XL HP BioShield Full Hood System

SKU S-3000-23

Choose it for: high-consequence pathogen care with splash or contact risk. The taped hood passes ASTM F1670-14 and F1671-13, and its skirts interface with most protective suits.

View product →

Sentinel XL HP Base Kit

SKU S-3000-12

Hood and cartridges sold separately

Choose it for: departments that need more than one configuration. Add a head cover, clear hood or BioShield hood with HEPA or OV/AG/HE cartridges, or a conversion kit.

View product →

The Sentinel XL Blower and Power Options

The blower is the same in every system on this page, and it runs on either battery type, so units can switch power source without changing anything else.

  • Housing Rugged, sealed nylon shell with a floating polycarbonate internal blower assembly, in a dual-chamber design for durability
  • Airflow and noise More than 230 lpm in HP hood systems, at a noise level below 75 dB
  • Weight 1.0 lb without the battery
  • Cartridge interface 40 mm military/NATO-style ports with integral blower gaskets
  • Low-voltage alarm Flashing LED and buzzer that warn the wearer to leave the contaminated area and recharge
  • Waist belt Quick-Loc click-on belt that accommodates up to a 55-inch waist and wipes clean with standard disinfectants

Rechargeable NiMH Battery

S-2003 · Standard System and Base Kit

8 h

Nominal runtime per charge

About 500 charge cycles and a 5-hour recharge on the Smart Battery Charger, which switches to trickle charge automatically. 1.65 lb.

Alkaline Battery Pack

S-4013 · Clear Hood and BioShield Systems

10 h

Nominal runtime per five Duracell D-cells

Nothing to charge, so readiness does not depend on charge state. Snaps directly onto the blower. 1.95 lb.

Power tip

Both packs fit every Sentinel XL blower. Adding an alkaline pack to a Standard System or Base Kit gives a unit in daily rotation a backup that is ready without a charging cycle.

Getting a New System Ready for Use

  1. 1

    Power

    Charge a NiMH battery for about five hours before first use, until the charger LED flashes green. For alkaline systems, load five D-cells into the pack.

  2. 2

    Prepare the head top and cartridges

    Remove the protective films from the visor, remove the sealed caps from the cartridges and fit them to the blower.

  3. 3

    Switch on and check airflow

    A short beep confirms start-up. Place the flow meter in the hose connector: the system is ready when the top of the cone sits above the indication line.

  4. 4

    Connect and don

    Screw the breathing tube hand tight onto the blower and the head top, fasten the waist belt with the blower attached, then put on the head top.

These steps summarize the Sentinel XL HP donning guide. Follow the user instructions supplied with the system for full details.

One Blower, More Applications

Every system on this page can be reconfigured by changing the head top and cartridges, which is how a Base Kit is completed and how an existing unit takes on a new role. Each kit below works with a Sentinel XL HP system:

Spares and Consumables for Sentinel XL HP Systems

Shop by Application

Frequently Asked Questions

What is the Sentinel XL HP PAPR system?

The Sentinel XL HP is a NIOSH-approved, loose-fitting powered air-purifying respirator designed to give healthcare professionals respiratory protection against a range of infectious diseases. It combines the Sentinel XL blower with a head cover (APF 25) or a clear or BioShield full hood (APF 1,000), HEPA or OV/AG/HE cartridges, and a rechargeable or alkaline battery. No fit testing is required.

What is the difference between the four Sentinel XL HP kits on this page?

The Standard System (S-3000-01) comes with a head cover, HEPA cartridges, a NiMH battery and the Smart Battery Charger. The Clear Hood System (S-3000-16) and BioShield Full Hood System (S-3000-23) come with their hood, HEPA cartridges and an alkaline battery pack. The Base Kit (S-3000-12) has the blower, NiMH battery and charger but no hood or cartridges. All four include the flow meter, breathing tube, Quick-Loc waist belt and a duffel bag.

Which hoods and cartridges can complete the Base Kit?

The Base Kit is NIOSH approved with the S-4001 head cover, the S-3101 clear hood or the S-2028 BioShield full hood, and each of those head tops is compatible with S-4002 HEPA and S-4012 OV/AG/HE cartridges. Buy them separately, or add a conversion kit that bundles a head top, breathing tube and cartridges.

How long does the NiMH battery take to charge?

About five hours. Charge a new battery for that long before first use: the charger LED flashes green when charging is complete, and the charger then switches to trickle charge automatically. The pack is rated for approximately 500 charge and discharge cycles.

What happens when the battery runs low?

The blower's low-voltage alarm sounds a buzzer and flashes the LED. When it does, the wearer should leave the contaminated area and recharge or replace the battery.

Can a Sentinel XL HP system be used for hazardous drugs or decontamination?

Yes. For hazardous drugs, fit S-4012 OV/AG/HE cartridges, sold separately, to any HP head top. For hospital decontamination, the S-5000-05 CBRN Conversion Kit converts the same blower to a NIOSH CBRN Cap 2 configuration with a butyl hood and CBRN cartridges.

How heavy and how loud is the Sentinel XL blower?

The blower weighs 1.0 lb without its battery, and runs below 75 dB. The NiMH battery adds 1.65 lb and the alkaline pack 1.95 lb. The blower clips to the Quick-Loc waist belt, which accommodates up to a 55-inch waist.

Can Sentinel XL HP systems be used in oxygen-deficient atmospheres?

No. They are air-purifying systems that filter the surrounding air and do not supply oxygen. NIOSH approvals apply to complete assemblies, so use the system only in the configurations listed on its approval label and follow the user instructions.

How do I equip several departments or sites?

Every system on this page can be ordered directly. For fleet purchasing, multi-site standardization or help choosing systems and conversion kits by department, request a quote or call ILC Dover on 469-822-8981, Monday to Friday, 08:00-16:30 CST.

Whether you need one ready-to-wear unit for an isolation room or a fleet of base kits configured department by department, the Sentinel XL HP gives you one blower platform from routine care to hazardous drugs and decontamination. For CBRN systems and escape respirators, see the full Advanced Respiratory Protection range.

Equipping a hospital with Sentinel XL HP?

Talk to the team about fleet purchasing, multi-site standardization or choosing systems and kits by department. Monday to Friday, 08:00-16:30 CST.

Request a quote 469-822-8981