Hoods & Head Covers

Sentinel PAPR Hoods and Head Covers: Head Cover, Clear Hood, BioShield and CBRN Butyl Hood

The head top is the part of a powered air-purifying respirator (PAPR) the wearer sees, feels and lives with for a whole shift, and it sets the protection level of the system. ILC Dover makes four loose-fitting head tops for the Sentinel XL blower: the Sentinel head cover at an assigned protection factor (APF) of 25, the XL clear hood and BioShield full hood at APF 1,000, and the butyl hood for CBRN work. None requires fit testing, each comes in a single size, and every product on this page is a genuine ILC Dover replacement, sold direct by the manufacturer.

25–1,000

Assigned protection factors, HP head tops

10,000

LRPL in the NIOSH CBRN PAPR standard, butyl hood

320°

Field of view, XL clear hood

1 size

Every head top, with no fit testing

Four Sentinel Head Tops

Three HP head tops share the same blower, breathing tube connection and cartridges, so a department can move between protection levels by changing the hood alone. The CBRN butyl hood is a separate assembly with its own integral breathing tube.

  • Sentinel Head Cover

    SKU S-4001

    APF 25

    2.5× the protection of an N95

    A half hood with a threaded breathing tube connection. Compatible with stethoscopes.

    Pack of 3 · Pack of 25

  • Sentinel XL Clear Hood

    SKU S-3101

    APF 1,000

    100× the protection of an N95

    A 320 degree field of view and no internal suspension. Accommodates most head, hearing and eye protection.

    Pack of 3 · Pack of 30

  • Sentinel XL BioShield Full Hood

    SKU S-2028

    APF 1,000

    Plus ASTM F1670 and F1671 barrier performance

    Sewn and taped seams, with internal and external skirts that interface with most protective suits.

    Pack of 3 · Pack of 25

  • Sentinel XL CBRN Butyl Hood Assembly

    SKU S-2001

    CBRN Cap 2

    The head top of the only NIOSH-approved Cap 2 loose-fitting CBRN PAPR

    A lay-flat butyl hood with an integral breathing tube and adjustable head band.

    View product →

Construction and Compatibility Compared

Protection factor is only part of the choice. How each head top seals, what it is made of and which cartridges it is approved with all differ:

Head top Fit and interface Construction Cartridges

Head cover

S-4001

Elasticized head band and face seal that sit under the chin and along the jawline

Coated, spun bonded polyolefin with a cushioned head strap. Impact resistant, optical grade polycarbonate visor with a chin panel that eliminates glare

HEPA P100 or OV/AG/HE

Clear hood

S-3101

Full hood with no internal suspension system, worn over most head, hearing and eye protection

Clear design for a 320 degree field of view. Latex free

HEPA P100 or OV/AG/HE

BioShield full hood

S-2028

Internal and external skirts that interface with most protective suits. Airflow vents between the two skirts and inflates the suit

Coated, spun bonded polyolefin with sewn and taped seams in all exterior locations. Cushioned head strap. Latex free

HEPA P100 or OV/AG/HE

CBRN butyl hood

S-2001

Cushioned, antimicrobial head strap with five adjustment positions, field replaceable, and an adjustable draw cord

Butyl-coated fabric with sewn and taped seams, a polycarbonate visor, an M40-style silicone exhaust valve and an integral breathing tube in a butyl sheath

CBRN Cap 2 only

NIOSH approvals apply to complete assemblies, so use each head top only in the Sentinel configurations listed on the approval label.

Choosing a Head Top for the Task

  • Routine airborne isolation The head cover is the everyday option, and its stethoscope compatibility suits bedside care.
  • Visibility and other PPE The clear hood gives APF 1,000 with a 320 degree view, and fits over most head, hearing and eye protection.
  • Splash, contact or a full suit The BioShield full hood adds taped seams that pass ASTM barrier testing and skirts that interface with the suit.
  • Hazardous drugs (USP 800) Any HP head top with OV/AG/HE cartridges. The head cover or hood decision depends on the drug's concentration and toxicity.
  • CBRN and decontamination The CBRN butyl hood, with S-2016 Cap 2 cartridges on the Sentinel XL blower.

Selection tip

ILC Dover's USP 800 guidance is to select a hood rather than a head cover whenever the hazardous drug exposure is uncertain. For clinical hood selection in more depth, see infectious disease protection and healthcare PAPR programs.

Pack Sizes and Part Numbers

HP hoods and head covers are consumables with a finite service life, so they are packed for unit-level stock and for central supply. The CBRN butyl hood is sold as a single assembly.

Packs of 3

Head cover (S-4001-3), clear hood (S-3101-3) and BioShield hood (S-2028-3), for departmental replacements

Packs of 25 and 30

Head cover (S-4001-25), BioShield hood (S-2028-25) and clear hood (S-3101-30), for central supply and outbreak reserve

Single assembly

CBRN butyl hood (S-2001), supplied with its integral breathing tube

Putting a New Head Cover into Service

  1. 1

    Remove the visor films

    Peel the protective film off both the outer and the inner side of the visor before first use.

  2. 2

    Check airflow

    With cartridges fitted and the blower switched on, place the Sentinel Flow Meter in the hose connector. The system is ready when the top of the cone sits above the indication line.

  3. 3

    Connect the breathing tube

    Screw the tube onto the blower, then onto the head cover connector, hand tight at both ends.

  4. 4

    Don and adjust

    Put on the belt-mounted blower, open the head cover, place it over the head and adjust the chin opening. The elasticized head band and face seal should touch the face under the chin and along the jawline.

These steps follow the Sentinel XL HP donning guide for the head cover. The full donning procedure for every hood is in the user instructions supplied with the system.

When to Replace a Hood or Head Cover

ILC Dover recommends inspecting the system after each use. Replace the head top if you answer yes to any of these:

  • Hood or head cover Are there tears or punctures, including in the stitching, that could let contaminated air in?
  • Visor Are there scratches or distortions that make it difficult to see through?
  • Breathing tube Are there tears, holes or cracks along its length, or is it becoming stiff or inflexible?

Cleaning note

ILC Dover does not recommend or endorse specific cleaning procedures, methods or frequencies for its head tops. Any protocol is the end user's responsibility, taking into account how often the equipment is used, whether it is shared between users, the environment, and the type and level of contamination.

Head Tops in Sentinel Systems and Conversion Kits

Hood and head cover packs contain head tops only. The blower, battery and cartridges are sold separately, and the HP head tops also need a breathing tube. To buy a head top with everything it needs, choose a system or a conversion kit:

Replacement cartridges are in Filters & Cartridges.

Shop by Application

Frequently Asked Questions

What is the difference between a PAPR head cover and a PAPR hood?

The Sentinel head cover (S-4001) is a half hood: an elasticized head band and face seal sit under the chin and along the jawline, and it carries an APF of 25. The clear hood and BioShield are full hoods, and both carry an APF of 1,000. The BioShield adds internal and external skirts that interface with most protective suits.

Do Sentinel hoods and head covers come in different sizes?

No. Every Sentinel head top is single size, so there is no need to buy and stock multiple sizes, and none requires fit testing when used in an approved system configuration. The CBRN butyl hood adjusts with a five-position head strap and a draw cord.

Which cartridges can be used with each hood?

The head cover, clear hood and BioShield full hood are all compatible with S-4002 HEPA P100 cartridges for particulates and S-4012 OV/AG/HE cartridges where organic vapors or acid gases are present. The CBRN butyl hood is used only with S-2016 CBRN Cap 2 cartridges.

Should I choose a head cover or a hood for hazardous drugs?

ILC Dover's USP 800 guidance is that the choice depends on the concentration and toxicity of the drug, and that a hood should be selected if you are uncertain. Any of the three HP head tops can be used with OV/AG/HE cartridges, and the BioShield HD Conversion Kit (S-3000-31) packages the BioShield hood with them.

Can I wear glasses, hearing protection or a hard hat under the clear hood?

The Sentinel XL clear hood has no internal suspension system and accommodates most head, hearing and eye protection, which is why it is often chosen where other PPE has to be worn at the same time.

Does the CBRN butyl hood need a separate breathing tube?

No. The S-2001 is an assembly: its flexible breathing tube, reinforced with a butyl sheath, is an integral part of the hood. The HP head cover, clear hood and BioShield hood connect to the blower with a separate breathing tube, which is included in Sentinel HP systems and conversion kits.

How do I prepare a new head cover for use?

Remove the protective film from both the outer and inner side of the visor, check blower airflow with the flow meter, and connect the breathing tube hand tight to the blower and the head cover. When donned, the elasticized head band and face seal should touch the face under the chin and along the jawline. Follow the user instructions for full details.

When should a hood or head cover be replaced?

Inspect after each use. Replace a hood or head cover with any tear or puncture, including in the stitching, or with visor scratches or distortions that make it difficult to see through. Replace a breathing tube that has tears, holes or cracks, or has become stiff.

How do I order hoods and head covers for several departments or sites?

Every hood and head cover pack above can be ordered directly. For standing replenishment, multi-site supply or help choosing head tops by department, request a quote or call ILC Dover on 469-822-8981, Monday to Friday, 08:00-16:30 CST.

From a pack of three head covers for one ward to a central reserve of clear and BioShield hoods, ILC Dover supplies the head tops that keep each Sentinel configuration in service and within its approval. For blowers, batteries, complete systems and conversion kits, see the full Advanced Respiratory Protection range.

Stocking hoods across your departments?

Talk to the team about standing replenishment, multi-site supply or choosing head tops by department. Monday to Friday, 08:00-16:30 CST.

Request a quote 469-822-8981