ILC Dover respiratory protection brings two product families together in one place. Sentinel powered air-purifying respirator (PAPR) components cover what it takes to run and maintain a PAPR: hoods and head covers, HEPA P100 and CBRN cartridges, blower, batteries and charger, and the accessories that keep a unit comfortable and verified before use. SCape air-purifying escape respirators provide 30 minutes of NIOSH-approved protection for leaving a contaminated area. Everything here is sold direct by ILC Dover, the manufacturer.

PAPR Hoods and Head Covers

Four Sentinel head tops span the protection levels most programs need. None of them requires fit testing.

For help matching a hood to clinical exposures, see infectious disease respiratory protection.

PAPR Filters and Cartridges

Sentinel cartridges come in two types. Which one you need is set by the configuration you are running, not by preference.

  • Sentinel HEPA Cartridges (3 Pack of 2 or 25 Pack of 2) - HEPA P100 filters that remove at least 99.97% of airborne particles 0.3 microns and larger. Used with the head covers and particulate hoods above.
  • Sentinel CBRN Cartridges, 3 EA - 40mm threaded cartridges rated against military warfare agents and biological, industrial chemical and nuclear particulate threats. Used with the butyl hood.

PAPR Blower, Batteries and Charger

PAPR Accessories

Converting a Sentinel for CBRN Work

The Sentinel XL CBRN Conversion Kit turns a Sentinel HP system into a configuration for CBRN and hospital decontamination operations. In the kit: the butyl hood assembly with breathing tube, three CBRN cartridges and the CBRN CAP 2 user's manual. The Sentinel XL CBRN is a NIOSH CAP 2 CBRN PAPR, tested against live warfare agents. For how powered air and escape protection work together in a CBRN program, see CBRN respiratory protection.

SCape Escape Respirators

Two NIOSH-approved air-purifying escape respirators round out the range. The SCape CBRN30 Air Purifying Escape Respirator (TC-14G-0277) covers CBRN threats, and the SCape CO/CBRN30 Air Purifying Escape Respirator (TC-14G-0312) adds carbon monoxide. Both give 30 minutes of powered, filtered airflow. For how escape respirators work and how to choose between them, see escape respirators.

Shop by Application

  • Healthcare - building and running a hospital PAPR program
  • Infectious Disease - hoods and HEPA filtration for airborne pathogens
  • CBRN - powered air and escape protection against chemical, biological, radiological and nuclear threats
  • Government - escape respirators for agencies, federal facilities and protective details
  • Escape - emergency escape respirators for any facility

Frequently Asked Questions

Are these genuine ILC Dover parts?

Yes. Every product in this category is made and sold by ILC Dover. NIOSH approvals apply to specific assemblies of approved components, so replacement hoods, cartridges and batteries should be the parts specified for your configuration.

Which cartridge do I need, HEPA or CBRN?

It depends on the configuration. Sentinel HEPA P100 cartridges are for particulate and biological protection with the HP head cover, clear hood and BioShield hood. Sentinel 40mm CBRN cartridges are for CBRN configurations using the butyl hood assembly.

Should I choose a rechargeable or alkaline battery pack?

Rechargeable NiMH suits units in daily use: up to 8 hours per charge, recharged in the blower with the Smart Battery Charger. The alkaline pack suits reserve or infrequently used units, because it runs on standard D-cells for up to 10 hours and does not depend on a charging routine.

Is the Sentinel XL blower sold separately?

Yes. The Sentinel XL Blower Assembly (S-2002) is available on its own, and it works with both the rechargeable and alkaline battery packs.

Can I buy a complete Sentinel XL system?

The store does not currently list complete systems as bundles. Every component of a Sentinel configuration can be ordered individually here. For help specifying a complete setup, request a quote or call 469-822-8981.

Are Sentinel and SCape products latex free?

Yes. ILC Dover's PAPR systems and accessories are latex free across the Sentinel XT, Sentinel XE, Sentinel XL and SCape product lines.

Do you ship outside the United States?

Online orders ship to addresses in the United States. If your shipping address is outside the US, contact ILC Dover directly.

How do I place a volume or multi-site order?

Any item in this category can go straight into the cart. For multi-site programs, standing orders or configuration advice, request a quote or call ILC Dover on 469-822-8981, Monday to Friday, 08:00-16:30 CST.

From a single replacement cartridge to a full program of hoods, blowers and escape respirators, ILC Dover supplies the respiratory protection in this category direct, with the product knowledge of the team that designs it.