Sentinel XL Clear Hood (Pack of 30)
SKU: S-3101-30



SKU: S-3101-30
- Pack of 30: 30 S-3101 clear hoods, sized for stocking high-use clinical units and outbreak reserves.
- APF 1,000 protection: 100 times the protection of an N95, with no fit testing when used in an approved system configuration.
- 320-degree field of view: the clear hood design provides a 320-degree field of view for increased safety.
- No internal suspension: for increased comfort, and the hood accommodates most head, hearing and eye protection.
- Compatible filters: S-4002 HEPA cartridges for infectious-disease protection or S-4012 OV/AG/HE cartridges for hazardous-drug protection.
- Also available: a pack of 3, plus the HP conversion kit with breathing tube and HEPA cartridges.
- Product ID: ILC Dover S-3101-30
$2,650.00
Prices for items exclude shipping costs and taxes. Depending on your delivery address, taxes may vary at checkout.This pack contains 30 S-3101 Sentinel XL Clear Hoods, to stock high-use clinical units and outbreak reserves with replacement hoods for Sentinel XL PAPR systems.
The clear hood has an assigned protection factor (APF) of 1,000, or 100 times the protection of an N95, and requires no fit testing when used in an approved system configuration. The clear hood design provides a 320-degree field of view for increased safety. The hood has no internal suspension system, for increased comfort, accommodates most head, hearing and eye protection, and comes in a single size.
The clear hood connects to the Sentinel XL blower with the S-4005 breathing tube and is used with S-4002 HEPA cartridges for infectious-disease protection or S-4012 OV/AG/HE cartridges for hazardous-drug protection. The Sentinel XL HP Clear Hood PAPR Conversion Kit includes a clear hood, breathing tube and HEPA cartridges. The clear hood is also sold in a pack of 3.
ILC Dover recommends inspecting your system after each use. Replace any clear hood with tears or punctures, including in the stitching, or with visor scratches or distortions that make it difficult to see through.
What's included
- 30 S-3101 Sentinel XL Clear Hoods
- Blower, breathing tube, battery and cartridges are sold separately.
Key specifications
- Quantity: 30 clear hoods
- Protection: APF 1,000, 100 times the protection of an N95, no fit testing in approved configurations
- Clear hood: 320-degree field of view, no internal suspension, single size
- Compatible filters: S-4002 HEPA P100, S-4012 OV/AG/HE
- Compatible with: Sentinel XL blower with the S-4005 breathing tube
- Latex-free
Which Sentinel XL hood or head cover do I need?
All four head tops run on the same Sentinel XL blower, so the choice comes down to how much protection you need and which hazard you are working against.
| Sentinel XL Head Cover S-4001 | Sentinel XL Clear Hood S-3101 | Sentinel XL BioShield Full Hood S-2028 | Sentinel XL CBRN Butyl Hood Assembly S-2001 | |
|---|---|---|---|---|
| Protection | APF 25 2.5 times the protection of an N95 | APF 1,000 100 times the protection of an N95 | APF 1,000 100 times the protection of an N95 | CAP 2 NIOSH CBRN CAP 2 with a 10,000 LRPL, in the approved Sentinel XL CBRN configuration |
| Use it for | Infectious disease care with HEPA cartridges, or hazardous drug handling with OV/AG/HE cartridges | Infectious disease care with HEPA cartridges, or hazardous drug handling with OV/AG/HE cartridges | Infectious disease care with HEPA cartridges, or hazardous drug handling with OV/AG/HE cartridges | CBRN protection for emergency preparedness and decon teams |
| What sets it apart | Wide field of view, accommodates stethoscopes, secure threaded breathing tube connection. A single size removes the need to stock multiple sizes. | 320-degree field of view. No internal hood suspension system, for comfort, and it accommodates most head, hearing and eye protection. | Sewn and taped seams pass ASTM F 1670-14 and ASTM F 1671-13, required by the CDC for protection against synthetic blood and blood-borne pathogen penetration. Internal and external skirts interface with most protective suits. | Lay-flat butyl-coated hood with sewn and taped seams and a replaceable antimicrobial head strap. The flat fold reduces storage issues. |
| Fit testing | Not required. Single size. | Not required. Single size. | Not required. Single size. | Not required. Single size. |
| Cartridges used with | S-4002 HEPA P100 S-4012 OV/AG/HE | S-4002 HEPA P100 S-4012 OV/AG/HE | S-4002 HEPA P100 S-4012 OV/AG/HE | S-2016 CBRN CAP 2 only. S-2016 cartridges are for use with this hood only. |
| Breathing tube | Needs the S-4005 breathing tube, not included | Needs the S-4005 breathing tube, not included | Needs the S-4005 breathing tube, not included | Included. The breathing tube is an integral part of the hood. |
| Supplied in these systems | Sentinel XL HP Standard PAPR System | Sentinel XL HP Clear Hood PAPR System | Sentinel XL HP BioShield Full Hood PAPR System | CBRN Standard, rechargeable CBRN Standard, alkaline CBRN Deluxe, rechargeable CBRN Deluxe, alkaline |
| Conversion kits | HP Head Cover PAPR Conversion Kit | HP Clear Hood PAPR Conversion Kit | HP BioShield Full Hood PAPR Conversion Kit HD BioShield Full Hood PAPR Conversion Kit | CBRN PAPR Conversion Kit |
| Pack sizes | Pack of 3 Pack of 25 | Pack of 3 Pack of 30 | Pack of 3 Pack of 25 | Single hood assembly |
All Sentinel XL hoods and head covers are latex free and are part of an air-purifying system that does not supply oxygen, so none are for use in oxygen-deficient atmospheres. NIOSH approvals apply to complete assemblies: use each hood or head cover only in the Sentinel configurations listed on the approval label, and follow the user instructions.